Diskriminering og reparasjon av vanlige feil i FANUC.
SVM -feil: LED -skjerm 2, hvordan fjerne alarmen. SPM -feil: LED -skjerm 19, hvordan fjerner du alarmen?
SVM alarmkode 2.
(1) Innhold: Frekvensomformeren kontrollerer lavspenningen til strømforsyningen.
(2) Hovedårsaker og eliminasjonsmetoder.
(a) bekrefter 3 - faseinngangsspenningen til forsterkeren (skal være større enn eller lik 0,85 ganger den nominelle inngangsspenningen).
(b) bekrefter 24V strømforsyningsspenningsutgang fra PSM (normal: 22,8V eller høyere).
(c) Bekreft kontakten, kabel (cxa2a/b).
(d) Bytt ut SVM.
SPM alarmkoder 19, 20.
Offsetspenningen til U -fase (alarmkode 19) og V -fase (alarmkode 20) gjeldende deteksjonskrets er for stor. Opprettet når du er slått på.
Når det oppstår en alarm, vennligst bytt ut SPM. Når SPM Control Printed Circuit Board nettopp er erstattet, må du bekrefte innsetting av kontakten mellom strømmenheten og SPM -kontrolltrykte kretskort.